713-574-6661

menu-button
  • Home
  • »
  • Rentals
  • »
  • Thermal Oxidizer Rental: Model CEF-5

High VOC Thermal Oxidizer Rental: Model CEF-5

Our growing technical services department continues to expand its capabilities and is now officially its own division. PolSys Services is our exclusive dedication to providing rental air pollution control systems, including both rental oxidizers and scrubbers. Contact PolSys Services at 713-999-1100 or at www.polsysservices.com for rental system inquiries and for more information on this company division.


The CEF-5 is a trailer mounted, natural gas or propane thermal oxidizer designed to treat hydrocarbon contaminated air streams. It can handle both low VOC contaminated streams <50% LEL and high VOC streams, >50% LEL. The unit and controls can be converted to operate with a catalyst module insert. The oxidizer is designed to operate completely independent of the process and is equipped with an enable disable signal interface in the system control panel.

  • Base System Components
  • Epoxy Coated Carbon Steel Outer Shell
  • High Temperature Ceramic Insulation
  • Trailer Mounted
  • Two (2) Oxidizer Process Blowers w/ VFDs
  • Flame Arrestor for low VOC process
  • Flame Trap for high VOC process
  • Natural Gas or Propane Primary Burner
  • NFPA Compliant Gas Train
  • Stainless Steel Exhaust Stack

Specifications

  • Maximum Air Flow Capacity: 3,050 SCFM
  • Minimum Air Flow: 800 SCFM
  • Maximum Inlet Temperature from Source: 300 ?F
  • Burner Capacity: 4,800,000 BTUH
  • Inlet Connection: 11” Dia.
  • Stack Height: 18’ 7” Above Ground
  • Stack Diameter: 30”
  • Maximum Thermal Operating Temperature: 1800 ?F
  • Optional Catalyst Module: Precious Metal Monolith
  • Catalyst Operating Temperature: 650 ?F
  • Maximum Exit Catalyst Temperature: 1200 ?F
  • Maximum Hydrocarbon Throughput:
  • High VOC Mode ~5 MMBTUH or 750 SCFM
  • Thermal Mode <50% LEL
  • Catalytic Mode <25% LEL
  • Oxidizer Process Blowers: 7.5 HP
  • Time To Reach Operating Temperature: 15 Minutes from cold start
  • Power Requirements: 460/3/60, 26 FLA
  • Trailer: 16,000 lb Dual Axle

Download the specs sheet on Thermal Oxidizer Rental Model CEF-5

  • UL Listed, Nema 4 Control Panel
  • PLC w/ First Outage Fault Finder
  • Thermocouple Temperature Control
  • Digital Chart Recorder
  • Automatic Purge / Process Damper
  • Air Flow Sensor and Gauge
  • Differential Pressure Transmitter
  • Instrumentation Package

Contact us today to request a quote from Pollution Systems
or call us at 713-574-6661

Follow us for Pollution System Solutions updates!

Today's looking good for Texas! https://t.co/NYyMwzbAPI2 months, 1 week ago

Did you know some companies install wet scrubbers solely for odor control? Because nobody should work for companies that stink... – 3 months, 1 week ago

Did you know that humans and animals produce ammonia naturally? https://t.co/xQOMIfFNHC3 months, 3 weeks ago